Summary for Test 2023-03-15-2-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 993493 DEA: 100Q1224 EFIS: 1014000168 |
|---|---|
| DIST-CO-RTE-PM | 10-MER-99-28.2/R37.3 |
| Award Date | 03/30/2022 |
| Closeout Date | 04/30/2025 |
| Work Description | WIDEN CONCRETE PAVEMENT LANES AND BRIDGES. |
| Location Description | MERCED COUNTY IN AND NEAR LIVINGSTON FROM 0.8 MILE SOUTH OF HAMMATT AVENUE OVERCROSSING TO STANISLAUS COUNTY LINE |
| QA Service Level | 1 (Verified on 01/10/2022) |
Sample Information
| Sample Taken Date | 03/15/2023 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/21/2023 |
| Sample type | Quality Assurance | A brief description of the sample | HRC 500/510 |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | shalvin | Last name of sampler or witnessed by | prasad |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CMC HRC | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | |
| Rebar Size | #11 | Coupler Model | HRC 500/510 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 74126669 73126153 | Rebar Heat Number(s) | 6036726 |
| Rebar Size 2 | Coupler Unique ID | TP-17-03 |
Test Details
DIME Sample ID: 2023-03-15-2
DIME Test ID: 2023-03-15-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-03-21
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 03/21/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID:
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | No. 11/36mm | 1 | 0 | 1.56 | 162137 | 103934 | Ok Necking | rmacias |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 3/21/2023 ✔