Summary for Test 2023-03-16-6-3
Test performed: AASHTO T315-22Project Information
Project Identifiers | Project ID: 994212 DEA: 010E0104 EFIS: 0113000090 |
---|---|
DIST-CO-RTE-PM | 01-HUM-36-0.1/1.65 |
Award Date | 12/07/2022 |
Closeout Date | Not set |
Work Description | Alton 015 Shoulder Widening |
Location Description | HUMBOLDT COUNTY NEAR ALTON FROM 0.1 MILE EAST OF ROUTE 36/101 SEPARATION TO 1.7 MILES EAST OF ROUTE 36/101 SEPARATION |
QA Service Level | 1 (Verified on 09/09/2022) |
Sample Information
Sample Taken Date | 03/16/2023 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/20/2023 |
Sample type | Department Acceptance | A brief description of the sample | binder sample JMF |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Source |
First name of sampler or witnessed by | jayce | Last name of sampler or witnessed by | Brown |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero Benicia | Transportation Laboratory (TL) Number | 000000 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | Mercer Fraser Fortuna Plant | |
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2023-03-16-6
DIME Test ID: 2023-03-16-6-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2023-03-21
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 03/20/2023
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.243 kPa
Phase Angle (δ) (for the 10 cycles): 82.4 degree
Complex Modulus (G*) (for the 10 measurements): 2.025 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 2.04 kPa
General comments (publicly viewable) (Max 1000 characters): OG - tested at 64C for information only
Test was verified on 3/21/2023 ✔