Summary for Test 2022-11-15-74-3
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 88885 DEA: Geotechnical Investigations EFIS: Geotechnical Investigations |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for geotechnical investigations. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/15/2022 | Sample Unique Key | 74 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/03/2023 | Sample type | Per Request |
| A brief description of the sample | Boring | The quantity of what the sample constitutes | NA |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Mohammed |
| Last name of sampler or witnessed by | Iqbal | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | NA | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 07-LA-57-PM7.7 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2022-11-15-74
DIME Test ID: 2022-11-15-74-3
Testing Lab: CT HQ - FFS - Corrosion Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2023-03-14
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Payam Vosoughi
Date of test: 02/03/2023
Minimum soil resistance of the lab measurement: 156 Ohms
Soil sample temperature: 22.3 C
Soil box constant: 5
pH of soil: 8.39
Minimum soil resistance corrected to 15.5: 182.52 Ohm-cm
Minimum soil resistivity at 15.5: 913 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): CR20230047
Test was verified on 3/14/2023 ✔