Summary for Test 2023-02-06-33-1

Test performed: AASHTO T48-18

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/06/2023 Sample Unique Key33
Date that the sample was received by the laboratory/organization performing the testing02/06/2023 Sample typeQuality Control
A brief description of the samplePG58-16 Asphalt binder The quantity of what the sample constitutes1 of 2 cans
From where was the sample collectedManufacturer First name of sampler or witnessed byDon
Last name of sampler or witnessed byConner Title of sampler Sr Asphalt Technician
Telephone number of sampler6614327352 Laboratory sample identification5816230206
Linked DIME Sample ID The fabricator/manufacturer/facility nameSan Joaquin Refinery, Bakersfield, CA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-16
ModifiedNo Lot number5816230206
Sublot number Tank number2002
Time of sample7:20 am HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2023-02-06-33
DIME Test ID: 2023-02-06-33-1
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2023-03-14

Test Results


Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Fahrenheit and mmHg
Input Type: Calculated
Tester's full name: Don Conner
Date of test: 02/06/2023
Observed Flash Point: 605 F
Ambient Barometric Pressure: 751 mmHg
Cleveland Open-Cup Flash Point in Fahrenheit: 605 F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/14/2023 ✔