Summary for Test 2023-01-28-16-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 88885 DEA: Geotechnical Investigations EFIS: Geotechnical Investigations |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for geotechnical investigations. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/28/2023 | Sample Unique Key | 16 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/06/2023 |
| Sample type | Per Request | A brief description of the sample | Culvert replacement |
| The quantity of what the sample constitutes | NA | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Mehrashk | Last name of sampler or witnessed by | Meydani |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | CR20230055 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 04-SoN-1-0.34 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-01-28-16
DIME Test ID: 2023-01-28-16-1
Testing Lab: CT HQ - FFS - Corrosion Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2023-03-14
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Payam Vosoughi
Date of test: 02/06/2023
Minimum soil resistance of the lab measurement: 599 Ohms
Soil sample temperature: 20.8 C
Soil box constant: 5
pH of soil: 6.76
Minimum soil resistance corrected to 15.5: 678.37 Ohm-cm
Minimum soil resistivity at 15.5: 3392 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/14/2023 ✔