Summary for Test 2023-03-06-9-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 993493
DEA: 100Q1224
EFIS: 1014000168
DIST-CO-RTE-PM10-MER-99-28.2/R37.3
Award Date03/30/2022
Closeout Date04/30/2025
Work DescriptionWIDEN CONCRETE PAVEMENT LANES AND BRIDGES.
Location DescriptionMERCED COUNTY IN AND NEAR LIVINGSTON FROM 0.8 MILE SOUTH OF HAMMATT AVENUE OVERCROSSING TO STANISLAUS COUNTY LINE
QA Service Level1 (Verified on 01/10/2022)

Sample Information

Sample Taken Date03/06/2023 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing03/06/2023 Sample typeQuality Assurance
A brief description of the sampleLenton form Savers couplers The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed bySai
Last name of sampler or witnessed byKasaraneni Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCMC Erico
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerErico Intermediate Assembler or Fabricator
Rebar Size#6 Coupler ModelLenton Form Saver
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)223612 M0028 Rebar Heat Number(s)6035384
Rebar Size 2 Coupler Unique IDST-17-05

Test Details

DIME Sample ID: 2023-03-06-9
DIME Test ID: 2023-03-06-9-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-03-07

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 03/07/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 6/19mm100.444157894496service splicermacias

General comments (publicly viewable) (Max 1000 characters): service splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 3/7/2023