Summary for Test 2023-01-23-20-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 994068 DEA: 081C7204 EFIS: 0813000003 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-R96.1/R124.3 |
Award Date | 08/02/2022 |
Closeout Date | 02/23/2024 |
Work Description | IMPORTED BORROW, SHOULDER BACKING, AND STRUCTURAL CONCRETE. |
Location Description | SAN BERNARDINO ABOUT 22 MILES NORTHEAST OF BARSTOW AT VARIOUS LOCATIONS FROM 0.3 MILE SOUTH OF HARVARD ROAD OVERCROSSING TO 0.1 MILE NORTH OF RASOR ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 09/30/2022) |
Sample Information
Sample Taken Date | 01/23/2023 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/25/2023 |
Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinders |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Alvin | Last name of sampler or witnessed by | Anggito |
Title of sampler | Assistant Structure Representative | Telephone number of sampler | |
Laboratory sample identification | 1047-04 | Linked DIME Sample ID | 2023-01-23-20 |
The fabricator/manufacturer/facility name | Robertsons | Transportation Laboratory (TL) Number | 081C720420230123 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | SC590B38 |
---|---|---|---|
The truck number from where the sample was collected | Not Provided on TL | The batch plant ticket number from where the sample was collected | Not Provided on TL |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Drainage System DS4.5.6 - Headwall | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-01-23-20
DIME Test ID: 2023-01-23-20-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-03-06
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 03/06/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 5.99 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 151720 lb
Maximum load on cylinder 2: 148830 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 42 days
Cross sectional area of cylinder 1: 28.18 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 5384.0 psi
Compressive strength of cylinder 2: 5264.6 psi
Compressive strength (to nearest 10 psi): 5320 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/6/2023 ✔