Summary for Test 2023-02-10-50-2
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 215486 DEA: 040A0204 EFIS: 0400000129 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-1-15-15.7 |
| Award Date | 05/04/2021 |
| Closeout Date | Not set |
| Work Description | Construct roadway and bridge with structural concrete and CIDH piling |
| Location Description | District-County-Route-Post Mile: 04-Son-1-R15.0/R15.7 |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 02/10/2023 | Sample Unique Key | 50 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/10/2023 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 HMA | The quantity of what the sample constitutes | 2 boxes |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Cody |
| Last name of sampler or witnessed by | Brown | Title of sampler | Inspector |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Bodean - Santa Rosa | |
| Transportation Laboratory (TL) Number | 101340 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | D04 JMF 22 011 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-02-10-50
DIME Test ID: 2023-02-10-50-2
Testing Lab: CT D04 - Petaluma Field Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-03-03
Test Results
Number of tests: 2
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Glenn Cea
Date of test: 02/14/2023
Method Performed: no data
Mass of container filled with water: 7389.4 grams
Mass of oven-dry sample in air for Sample 1: 2543.2 grams
Mass of container filled with the sample and water for Sample 1: 8953.4 grams
Mass of container filled with water: 7389.4 grams
Mass of oven-dry sample in air for Sample 2: 2538.2 grams
Mass of container filled with the sample and water for Sample 2: 8949.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.597
Specific Gravity for Sample 2: 2.596
Average Specific Gravity: 2.596
Theoretical maximum density at 25°C (77°F): 161.6 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): Theoretical Maximum Density =2.589
Test was verified on 3/3/2023 ✔