Summary for Test 2023-02-07-42-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 993508
DEA: 070W1104
EFIS: 0721000059
DIST-CO-RTE-PM07-LA-210-R35.9/R52.2
Award Date04/04/2022
Closeout Date09/24/2024
Work DescriptionCOLD PLANE OVERLAY, INDIVIDUAL REPLACEMENT SLAB AND TRAFFIC STRIPING.
Location DescriptionLOS ANGELES COUNTY FROM HIGHLAND AVENUE UNDERCROSSING IN DUARTE TO SAN ANTONIO WASH BRIDGE IN CLAREMONT.
QA Service Level1 (Verified on 04/19/2022)

Sample Information

Sample Taken Date02/07/2023 Sample Unique Key42
Date that the sample was received by the laboratory/organization performing the testing02/07/2023 Sample typeDepartment Acceptance
A brief description of the samplethree quarter inch HMA Type A aggregate The quantity of what the sample constitutes1 bag
From where was the sample collectedFabricator First name of sampler or witnessed byGerardo
Last name of sampler or witnessed byZubieta Title of samplerTEC
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Irwindale
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035
The fabricator's/manufacturer's product name for the sample3/4 HMA Aggregate The fabricator/manufacturer designation for the sampleDrum Plant
The plant number A detailed description of where the material sample was collectedConveyor Belt at Plant
Where the material sample would have been placed if not sampledHMA Mat Primary Aggregate Nominal Size3/4 inch
The concrete mix design number220831 A Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-02-07-42
DIME Test ID: 2023-02-07-42-1
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2023-03-02

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Gerardo Zubieta
Date of test: 02/07/2023
Cumulative Percent Passing
%
100 %
100 %
98 %
79 %
68 %
46 %
34 %
24 %
16 %
10 %
6 %
3.7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/2/2023 ✔