Summary for Test 2023-02-16-35-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 215456 DEA: 07293604 EFIS: 0713000238 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-405-14.3/15.8 |
| Award Date | 05/26/2021 |
| Closeout Date | 07/03/2025 |
| Work Description | CONSTRUCT AUXILIARY LANE AND WIDEN ON AND OFF RAMPS. |
| Location Description | LOS ANGELES COUNTY IN TORRANCE BETWEEN WESTERN AVENUE UNDERCROSSING AND WEST 182ND STREET |
| QA Service Level | 1 (Verified on 07/07/2021) |
Sample Information
| Sample Taken Date | 02/16/2023 | Sample Unique Key | 35 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/16/2023 |
| Sample type | Quality Assurance | A brief description of the sample | Native Material |
| The quantity of what the sample constitutes | 9765 square feet | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Dominic | Last name of sampler or witnessed by | Montemayor |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 23-0189 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | n/a | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | CTM 231 Test Holes | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-02-16-35
DIME Test ID: 2023-02-16-35-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-02-24
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Dominic Montemayor
Date of test: 02/16/2023
Gage No.: 6901
Test No.: 1
Nuclear By: Dominic Montemayor
Non-Bias Plan No.: 1
Depth: 5
Material No.: Subgrade
Material Type: Native Material
Impact By: Dominic Montemayor
Standard Count Density: 8794 g/cc
Count or Density 1: 14067 g/cc
Count or Density 2: 15594 g/cc
Count or Density 3: 12477 g/cc
Count or Density 4: 12825 g/cc
Count or Density 5: 12769 g/cc
Standard Count Moisture: 19335 g/cc
Moisture Count 1: 2880 g/cc
Moisture Count 2: 3237 g/cc
Moisture Count 3: 4454 g/cc
Moisture Count 4: 3680 g/cc
Moisture Count 5: 4205 g/cc
Sum of Count or Density: 67732 g/cc
Average of Count or Density: 13546 g/cc
Sum of Moisture Count: 18456 g/cc
Average of Moisture Count: 3691 g/cc
Count Ratio Density: 1.54
Count Ratio Moisture: 0.19
Calculated Percent Relative Compaction: 95.9 %
Reported Percent Relative Compaction: 96 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/24/2023 ✔