Summary for Test 2016-11-09-13-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/09/2016 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing11/16/2016 Sample typeQuality Assurance
A brief description of the sampleCoupon Casting The quantity of what the sample constitutes1
From where was the sample collectedFabricator First name of sampler or witnessed byMark
Last name of sampler or witnessed bySullivan Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameUrick
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)3L6
Part Number (s)SDI4 6A Material SpecificationA536
Grades80-55-06 Metal Foundry Manufacturer (Mill)Urick
Prestressing ManufacturerSDI

Test Details

DIME Sample ID: 2016-11-09-13
DIME Test ID: 2016-11-09-13-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-11-18

Test Results


Number of Samples: 1
Input Type: Calculated
Tester's full name: Arnold
Date of test: 11/17/2016
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
13L60.4950.1924609061071609.2Arnold

General comments (publicly viewable) (Max 1000 characters):
Test Graph