Summary for Test 2023-02-09-51-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993446
DEA: 120J34U4
EFIS: 1218000034
DIST-CO-RTE-PM12-ORA-55,55-29.6,R6.4/10.3
Award Date05/27/2022
Closeout DateNot set
Work DescriptionCONSTR BRIDGES, RW, SW, JPCP, HMA PVMT, DRAINAGE AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN IRVINE, SANTA ANA, AND TUSTIN ON ROUTE 5 AT NEWPORT AVENUE UNDERCROSSING AND ON ROUTE 55 FROM 0.4 MILE NORTH OF ROUTE 55/405 SEPARATION TO 0.1 MILE SOUTH OF ROUTE 5/55 SEPARATION
QA Service Level1 (Verified on 06/24/2022)

Sample Information

Sample Taken Date02/09/2023 Sample Unique Key51
Date that the sample was received by the laboratory/organization performing the testing02/09/2023 Sample typeQuality Assurance
A brief description of the sample3/4 HMA-A The quantity of what the sample constitutesbox of 3/4 HMA-A
From where was the sample collectedManufacturer First name of sampler or witnessed byJimmy
Last name of sampler or witnessed byPham Title of sampler
Telephone number of sampler Laboratory sample identification23-0105
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Corona
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-02-09-51
DIME Test ID: 2023-02-09-51-2
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-03-03

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: David Nguyen
Date of test: 02/10/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2231.1 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.34 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.45 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
2023AC-SP-0003pdf104.52 KB02/21/20232023-02-09-51-2   Info

Test was verified on 3/3/2023 ✔