Summary for Test 2023-01-30-3-4
Test performed: AASHTO T96-02r10Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/30/2023 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/02/2023 | Sample type | Verification |
| A brief description of the sample | Aggregate | The quantity of what the sample constitutes | 4 Bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | Erik |
| Last name of sampler or witnessed by | Svensson | Title of sampler | Consultant |
| Telephone number of sampler | Laboratory sample identification | 23-JMFPP-0011 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Construction | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-39-0002 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | 1073 | The fabricator/manufacturer designation for the sample | |
| The plant number | A detailed description of where the material sample was collected | HMA Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-01-30-3
DIME Test ID: 2023-01-30-3-4
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2023-02-17
Test Results
Input Type: Measured
Tester's full name: Jay Horton
Date of test: 02/13/2023
Grading designation: C
Mass of sample (before test): 5003 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4721 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3751 grams
Percent loss after 100 revolutions: 6 %
Percent loss after 500 revolutions: 25 %
General comments (publicly viewable) (Max 1000 characters): At 100 rev and 500 rev.
Test was verified on 2/17/2023 ✔