Summary for Test 2023-01-30-3-2

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/30/2023 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/02/2023
Sample typeVerification A brief description of the sampleAggregate
The quantity of what the sample constitutes4 Bags From where was the sample collectedSource
First name of sampler or witnessed byErik Last name of sampler or witnessed bySvensson
Title of samplerConsultant Telephone number of sampler
Laboratory sample identification23-JMFPP-0011 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-39-0002
The fabricator's/manufacturer's product name for the sample1073 The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedHMA Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-01-30-3
DIME Test ID: 2023-01-30-3-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2023-02-15

Test Results


Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 02/15/2023
Mass of saturated surface dry sample (before pycnometer) (S): 501.9 grams
Mass of the pycnometer with water and aggregate (C): 985.4 grams
Mass of the pycnometer with water (B): 675.3 grams
Mass of the oven dried sample (before pycnometer) (A): 490.3 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 501.9 grams
Mass of the oven dry aggregate (for absorption) (A): 490.3 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.556
Bulk specific gravity (SSD Basis): 2.617
Apparent specific gravity: 2.721
Absorption: 2.4 %
General comments (publicly viewable) (Max 1000 characters): Bulk specific gravity (SSD) of fine aggregate - Bulk specific gravity of fine aggregate - Bulk specific gravity of fine aggregate - Apparent specific gravity of supplemental fines - Absorption of fine aggregate.

Test was verified on 2/15/2023