Summary for Test 2023-01-26-48-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 215788 DEA: 101C7904 EFIS: 1016000046 |
|---|---|
| DIST-CO-RTE-PM | 10-MER-5-0.4 |
| Award Date | 12/17/2021 |
| Closeout Date | 05/04/2026 |
| Work Description | BUILDING WORK. |
| Location Description | MERCED COUNTY 0.4 MILE NORTH OF THE FRESNO COUNTY LINE AT THE JOHN "CHUCK" ERRECA SAFETY ROADSIDE REST AREA |
| QA Service Level | 1 (Verified on 06/03/2021) |
Sample Information
| Sample Taken Date | 01/26/2023 | Sample Unique Key | 48 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/31/2023 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 HMA-A | The quantity of what the sample constitutes | 16 boxes,5bags,2 cans |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | R |
| Last name of sampler or witnessed by | Contreras | Title of sampler | Lab Technician |
| Telephone number of sampler | Laboratory sample identification | 23-H-001 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Vernalis | |
| Transportation Laboratory (TL) Number | 039390 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-01-26-48
DIME Test ID: 2023-01-26-48-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-04-19
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Darrius Shuemake
Date of test: 02/07/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2122.0 g
Mass Loss: 137.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.79 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 5.55 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/19/2023 ✔