Summary for Test 2016-11-08-3-1
Test performed: ASTM A370-15Project Information
| Project Identifiers | Project ID: 8196 DEA: 59912684 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | |
| Location Description | |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/08/2016 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/09/2016 | Sample type | Quality Assurance |
| A brief description of the sample | A536 Ductile Iron | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Michelle |
| Last name of sampler or witnessed by | Haughey | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | SDI Farrar |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | J266 |
|---|---|---|---|
| Part Number (s) | SDI 1 38 HS Bar BP | Material Specification | A536 |
| Grades | 80-55-06 | Metal Foundry Manufacturer (Mill) | Farrar |
| Prestressing Manufacturer | SDI |
Test Details
DIME Sample ID: 2016-11-08-3
DIME Test ID: 2016-11-08-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-11-18
Test Results
Number of Samples: 1
Input Type: Calculated
Tester's full name: Arnold
Date of test: 11/16/2016
UTM: 67KIP
Temperature: 72 F
| Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | J266 | 0.503 | 0.1987 | 61076 | 105750 | 10.4 | Arnold |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 11/18/2016 ✔