Summary for Test 2023-01-12-54-2
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 994438 DEA: 120U1604 EFIS: 1223000043 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-1-12.07 |
| Award Date | 10/03/2022 |
| Closeout Date | 07/28/2023 |
| Work Description | CONSTRUCT SOLDIER PILE WALL AND PRE-CAST CONCRETE LAGGING, CEMENT SLURRY BACKFILL |
| Location Description | Culvert Failure and Shoulder Lost on SR-1 (PCH) in City of Laguna Beach. |
| QA Service Level | 1 (Verified on 12/15/2022) |
Sample Information
| Sample Taken Date | 01/12/2023 | Sample Unique Key | 54 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/13/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 4x8 concrete cylinders |
| The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Kenny | Last name of sampler or witnessed by | Do |
| Title of sampler | Telephone number of sampler | 9498727223 | |
| Laboratory sample identification | 23-0001 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Robertson's / Irvine | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | RRM20012 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Concrete from wheelbarrow | Where the material sample would have been placed if not sampled | Batch Plant Trial Batch |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-01-12-54
DIME Test ID: 2023-01-12-54-2
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-05-15
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Dan Morris
Date of test: 01/19/2023
Capped in accordance with?: ASTM C39 - Ground End
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.00 in
Maximum load on cylinder 1: 55430 lb
Maximum load on cylinder 2: 57640 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.62 in^2
Cross sectional area of cylinder 2: 12.56 in^2
Compressive strength (to nearest 10 psi): 4490 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/15/2023 ✔