Summary for Test 2023-02-09-13-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 993482 DEA: 060V2804 EFIS: 0616000124 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-184-L0.9/L1.1 |
| Award Date | 02/24/2022 |
| Closeout Date | 02/26/2024 |
| Work Description | PLACE HMA AND MINOR CONCRETE, REPLACE ELECTRICAL & LIGHTING SYSTEMS. |
| Location Description | KERN COUNTY NEAR LAMONT FROM 0.1 MILE SOUTH TO 0.1 MILE NORTH OF SUNSET BOULEVARD |
| QA Service Level | 1 (Verified on 01/03/2022) |
Sample Information
| Sample Taken Date | 02/09/2023 | Sample Unique Key | 13 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/09/2023 |
| Sample type | Department Acceptance | A brief description of the sample | Native Soil |
| The quantity of what the sample constitutes | 30 lBS | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Neale | Last name of sampler or witnessed by | Brown |
| Title of sampler | Tester | Telephone number of sampler | 6615498281 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Sta 15+10.11 to 21+00 | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Jobsite - Compacted SubBase | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-02-09-13
DIME Test ID: 2023-02-09-13-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-02-09
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 02/09/2023
Gage No.: 30699
Test No.: 17
Nuclear By: Neale Brown
Non-Bias Plan No.: 4- even
Depth: 8
Material No.: no data
Material Type: Brown- sandy silt
Impact By: Neale Brown
Standard Count Density: 1949 g/cc
Count or Density 1: 1060 g/cc
Count or Density 2: 966 g/cc
Count or Density 3: 1099 g/cc
Standard Count Moisture: 623 g/cc
Moisture Count 1: 156 g/cc
Moisture Count 2: 148 g/cc
Moisture Count 3: 154 g/cc
Sum of Count or Density: 3125 g/cc
Average of Count or Density: 1042 g/cc
Sum of Moisture Count: 458 g/cc
Average of Moisture Count: 153 g/cc
Count Ratio Density: 0.53
Count Ratio Moisture: 0.25
Calculated Percent Relative Compaction: 97.7 %
Reported Percent Relative Compaction: 98 %
General comments (publicly viewable) (Max 1000 characters): SE sidewalk Sta 15+10.11 to 21+00 wideth 10 ft Elv: FG
Test was verified on 2/9/2023 ✔