Summary for Test 2023-01-30-3-1
Test performed: AASHTO T27-14
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/30/2023 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/02/2023 | Sample type | Verification |
| A brief description of the sample | Aggregate | The quantity of what the sample constitutes | 4 Bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | Erik |
| Last name of sampler or witnessed by | Svensson | Title of sampler | Consultant |
| Telephone number of sampler | Laboratory sample identification | 23-JMFPP-0011 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Construction | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-39-0002 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | 1073 | The fabricator/manufacturer designation for the sample | |
| The plant number | A detailed description of where the material sample was collected | HMA Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-01-30-3
DIME Test ID: 2023-01-30-3-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2023-02-09
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Jay Horton
Date of test: 02/08/2023
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 2408.1 grams | ||||||
| grams | % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 43.3 grams | 98 % | |||||
| 258.1 grams | 89 % | |||||
| 931.3 grams | 61 % | |||||
| 916.7 grams | ||||||
| 390.2 grams | 35 % | |||||
| 594.8 grams | 21 % | |||||
| 703.3 grams | 14 % | |||||
| 774.5 grams | 9 % | |||||
| 819.0 grams | 7 % | |||||
| 844.0 grams | 4.8 % | |||||
| 847.1 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/9/2023 ✔
Warning: The test results shown on this page have been superseded and are invalid.