Summary for Test 2023-02-06-14-1
Test performed: CTM 342-August 2012Project Information
| Project Identifiers | Project ID: 993730 DEA: 010K7704 EFIS: 0121000008 |
|---|---|
| DIST-CO-RTE-PM | 01-MEN-101,162-14.6,15.9,0.7 |
| Award Date | 06/15/2022 |
| Closeout Date | 07/21/2023 |
| Work Description | Repair 3 Bridges |
| Location Description | MENDOCINO COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 04/19/2022) |
Sample Information
| Sample Taken Date | 02/06/2023 | Sample Unique Key | 14 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/06/2023 |
| Sample type | Department Acceptance | A brief description of the sample | Bridge deck surface |
| The quantity of what the sample constitutes | NA | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Jessie | Last name of sampler or witnessed by | Wilson |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Roadway/Bridge Surface | Pavement Surface Type | Not set |
|---|---|---|---|
| Type of Traffic Control Provided | Not set | DIST-CO-RTE | Not set |
| Direction of Travel | Not set | Post Mile | Not set |
| Lanes to be Tested | Not set | Station | Not set |
Test Details
DIME Sample ID: 2023-02-06-14
DIME Test ID: 2023-02-06-14-1
Testing Lab: CT HQ - FFS - Skid Testing
Test Method: CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Test Release Date: 2023-02-27
Test Results
Pavement or Bridge Deck?: Bridge Deck
Input Type: Measured
Tester's full name: Jessie Wilson
Date of test: 02/07/2023
Air Temperature: 32 F
Tire Pressure: 24 psi
Equipment PST #: 1000-7
Is Calibration within ± values: Yes
Weather: Overcast
Direction/Lane #: WB: Westbound Direction of Travel
Edge used to measure reference distance: no data
Edge used to measure position: Left of the right bridge wall
Reference Distance 1: 32 ft
Reference Distance 2: 35 ft
Reference Distance 3: 38 ft
Direction and Lane # for Stationing 1: WB
Direction and Lane # for Stationing 2: WB
Direction and Lane # for Stationing 3: WB
Position for Stationing 1: 5 ft
Position for Stationing 2: 5 ft
Position for Stationing 3: 5 ft
Percent Grade for 1st Stationing: 2.0 %
Percent Grade for 2nd Stationing: 2.0 %
Percent Grade for 3rd Stationing: 2.0 %
Corrected Coefficients of Friction for Stationing 1: 0.36
Corrected Coefficients of Friction for Stationing 2: 0.35
Corrected Coefficients of Friction for Stationing 3: 0.36
Average Coefficient of Friction: 0.36
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/27/2023 ✔