Summary for Test 2022-11-17-95-3

Test performed: ASTM C78-18

Project Information

Project IdentifiersProject ID: 214469
DEA: 030H08U4
EFIS: 0319000029
DIST-CO-RTE-PM03-SAC-50-L0.2/R6.1
Award Date06/30/2020
Closeout DateNot set
Work DescriptionSac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC
Location DescriptionFROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date11/17/2022 Sample Unique Key95
Date that the sample was received by the laboratory/organization performing the testing11/18/2022 Sample typeQuality Assurance
A brief description of the sampleCRCP Flexural Beam The quantity of what the sample constitutes8.5 yards
From where was the sample collectedSupplier First name of sampler or witnessed byJacob
Last name of sampler or witnessed byGregory Title of samplerMaterials Tester
Telephone number of sampler19163758706 Laboratory sample identification656
Linked DIME Sample ID The fabricator/manufacturer/facility nameElite - Granite Bradshaw
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameCRCP US50
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCT600
The truck number from where the sample was collected147 The batch plant ticket number from where the sample was collected788
Concrete batch plantElite Ready Mix Bradshaw The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSampled from chute of ready mix truck Where the material sample would have been placed if not sampledCRCP
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-11-17-95
DIME Test ID: 2022-11-17-95-3
Testing Lab: Blackburn Consulting
Test Method: ASTM C78-18: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading)
Test Release Date: 2023-02-08

Test Results


Number of specimens: 3
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Ernesto Sanchez
Date of test: 12/15/2022
Identification number: 7
Width of specimen: 5.8 inch
Width of specimen 2: 5.8 inch
Width of specimen 3: 5.8 inch
Depth of specimen: 5.9 inch
Depth of specimen 2: 5.9 inch
Depth of specimen 3: 5.9 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 8170 lb
Maximum load applied 2: 7990 lb
Maximum load applied 3: 8200 lb
Curing history and apparent moisture condition of the specimen: 28 days, wet
If specimen was capped, ground or if leather shims were used: Leather Shims
Defects in specimen: no
Age of specimen: 28 days
Age of specimen in hours: no data
Modulus of rupture: 730 psi
Modulus of rupture 2: 710 psi
Modulus of rupture 3: 730 psi
Modulus of rupture average: 725 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
3758.x 0H08U4 28 Day Beam Flextural Strength Report cast on 11-17-22pdf108.06 KB02/08/20232022-11-17-95-3   Info

Test was verified on 2/8/2023 ✔