Summary for Test 2023-01-26-47-3
Test performed: ASTM D624-00r20Project Information
| Project Identifiers | Project ID: 993915 DEA: 040Y9704 EFIS: 0422000388 |
|---|---|
| DIST-CO-RTE-PM | 04-SCL/SCL-101-47.89/47.89 |
| Award Date | 05/02/2022 |
| Closeout Date | 01/05/2024 |
| Work Description | Repair of girder 5 and replacement of girder 10, both in Span 1. |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/08/2022) |
Sample Information
| Sample Taken Date | 01/26/2023 | Sample Unique Key | 47 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/31/2023 | Sample type | Verification |
| A brief description of the sample | Bearing Pad | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Brad |
| Last name of sampler or witnessed by | Streeter | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Nucor Steel | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM1 - Elastomeric Bearing Pad | Mfg. Lot Number(s) | 22623-1 |
|---|---|---|---|
| Material/Compound/Elastomer ID | NA | Samples Representing | 2 |
| Description (size) | 1.15"x8"x24" | Comments | |
| Description (Number of Shims) | 2 | Type of Bearing Pad | Steel |
| Description (Thickness of Shims) | 14 gage | Manufacturer(s) | Scougal Rubber |
| Batch Number | NA |
Test Details
DIME Sample ID: 2023-01-26-47
DIME Test ID: 2023-01-26-47-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2023-02-07
Test Results
Number of specimens tested: 3
Input Type: Measured
Tester's full name: aauvinen
Date of test: 02/02/2023
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.059
Sample 1 Tear Strength: 203.9
Sample 2 Median Thickness: 0.056
Sample 2 Tear Strength: 224.8
Sample 3 Median Thickness: 0.056
Sample 3 Tear Strength: 229.4
UTM: 2kip
Median of the Tear Strength Values: 224.8 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Sample 2
Source: Bluehill Data Point File
Test graph for Sample 1
Source: Bluehill Data Point File
Test graph for Sample 3
Test was verified on 2/7/2023 ✔