Summary for Test 2023-01-27-23-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 993806
DEA: 07330504
EFIS: 0716000214
DIST-CO-RTE-PM07-LA-710-R15.1/21.9
Award Date08/02/2022
Closeout Date09/24/2024
Work DescriptionINSTALL HIGHWAY PLANTING AND PLACE MINOR CONCRETE.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM 0.2 MILE NORTH OF ROSECRANS AVENUE TO 0.1 MILE SOUTH OF ATLANTIC AVENUE UNDERCROSSING
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date01/27/2023 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/31/2023
Sample typeDepartment Acceptance A brief description of the sampleClass 3 Aggregate Base
The quantity of what the sample constitutesNA From where was the sample collectedJob Site
First name of sampler or witnessed byMichelangelo Last name of sampler or witnessed bySese
Title of samplerTET Telephone number of sampler
Laboratory sample identification23-013 Linked DIME Sample ID
The fabricator/manufacturer/facility namenNA Transportation Laboratory (TL) Number261748
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)NA
The fabricator's/manufacturer's product name for the sampleNA The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedMVP 5
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberNA Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-01-27-23
DIME Test ID: 2023-01-27-23-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2023-02-01

Test Results


Number of tests: 1
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 02/01/2023
Temperature correction: 0
Temperature of solution: 75
Clay reading (test 1): 5.2
Sand reading (test 1): 3.3
Sand equivalent (test 1): 64
Sand equivalent before temperature correction: 64
Sand equivalent after temperature correction: 64
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/1/2023