Summary for Test 2023-01-19-5-4

Test performed: ASTM A615-20

Project Information

Project IdentifiersProject ID: 993782
DEA: 07339604
EFIS: 0717000157
DIST-CO-RTE-PM07-LA-14-R29.0/R29.5
Award Date07/06/2022
Closeout Date11/05/2025
Work DescriptionCONSTRUCT SLOPE BETTERMENT.
Location DescriptionLOS ANGELES COUNTY IN SANTA CLARITA FROM 0.9 MILE NORTH OF PLACERITA CANYON ROAD UNDERCROSSING TO 0.2 MILE SOUTH OF GOLDEN VALLEY ROAD OVERCROSSING
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date01/19/2023 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing01/25/2023 Sample typeQuality Assurance
A brief description of the sample#8 Gr 80 Bar The quantity of what the sample constitutes5251
From where was the sample collectedManufacturer First name of sampler or witnessed byJacob
Last name of sampler or witnessed byGarcia Title of samplerQuality Assurance Inspector
Telephone number of sampler3109128014 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNucor Skyline
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL169-001-23
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade80
Threaded Bar Type Rebar Size#8
Nut Specification for Threaded BarASTM A36/ ASME SA-36 System ManufacturerNurcor Skyline
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)3700031281,3700031282,3700035231,3700035232,3
Nut Heat Number(s)B2615 Bar Lot Number
Nut Lot Number6016 Coupler Heat Number(s)
Coupler Grade

Test Details

DIME Sample ID: 2023-01-19-5
DIME Test ID: 2023-01-19-5-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2023-02-03

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 01/30/2023
UTM: 400kip
Temperature: 72 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
1No.8/25mm0.791114688359912.27A615 Bar and Nut Heat 3700031282spaine

General comments (publicly viewable) (Max 1000 characters): A615 Bar and Nut Heat 3700031282
Test Graph
Source: Bluehill Data Point File
WARNING: strain or stress not found in data points imported from Instron machine.

Test was verified on 2/3/2023 ✔