Summary for Test 2023-01-23-4-3
Test performed: ASME B1.2-83r17Project Information
| Project Identifiers | Project ID: 215443 DEA: 042J8024 EFIS: 0419000294 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-80-3.8/5.0 |
| Award Date | 04/20/2021 |
| Closeout Date | 01/03/2025 |
| Work Description | PAINT STEEL STRUCTURE. |
| Location Description | THE CITY AND COUNTY OF SAN FRANCISCO FROM 16TH STREET TO 4TH STREET. |
| QA Service Level | 1 (Verified on 02/23/2021) |
Sample Information
| Sample Taken Date | 01/23/2023 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/24/2023 |
| Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
| The quantity of what the sample constitutes | 17 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpenter |
| Title of sampler | QA | Telephone number of sampler | 4156081742 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-008-23 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 2613-01 |
|---|---|---|---|
| Heat Number(s) | 10662050, 8000014475, 32028550 | Nut Mfg. Lot Number(s) | 472199B |
| Washer Mfg. Lot Number(s) | 167117 | Bolt Specification | A325 |
| Bolt Length(s) | 4" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 7/8" X 4" | Bolt Mfg. Lot Number | L833RI |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2023-01-23-4
DIME Test ID: 2023-01-23-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Test Release Date: 2023-01-27
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 01/27/2023
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: L833R1
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 USA LE
Size: .875 in
Bolt Length: 4 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/27/2023 ✔