Summary for Test 2016-11-07-7-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 211657 DEA: 074P1304 EFIS: 0715000259 MINOR: 07A3986 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-33-6.5/7.0 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | In Ventura County |
| QA Service Level | 1 (Verified on 08/18/2016) |
Sample Information
| Sample Taken Date | 11/07/2016 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/10/2016 |
| Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Gary | Last name of sampler or witnessed by | MaComb |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | TNT Rebar Cascade | Transportation Laboratory (TL) Number | C970387 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L1012816 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 001916 |
| Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 5 |
| Diameter of Hoop | 3'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-11-07-7
DIME Test ID: 2016-11-07-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-11-16
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 11/15/2016
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | #5/16mm | 0.31 | 29090 | 93840 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 11/16/2016 ✔