Summary for Test 2023-01-19-4-3
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 993788 DEA: 033F0724 EFIS: 0322000010 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-51-2.5/3.3 |
| Award Date | 04/22/2022 |
| Closeout Date | 08/09/2024 |
| Work Description | Procure steel girders |
| Location Description | District-County-Route-Post Mile: 03-Sac-51-2.5/3.3 |
| QA Service Level | 1 (Verified on 04/25/2022) |
Sample Information
| Sample Taken Date | 01/19/2023 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/24/2023 | Sample type | Quality Assurance |
| A brief description of the sample | TC Fastener Assemblies | The quantity of what the sample constitutes | 1,870 |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Edward |
| Last name of sampler or witnessed by | Leach | Title of sampler | QA |
| Telephone number of sampler | 7072903887 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | St. Louis Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 100110141 223652 | Nut Mfg. Lot Number(s) | 37394-223652 |
| Washer Mfg. Lot Number(s) | E3382 | Bolt Specification | F1852 |
| Bolt Length(s) | 3" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | Mech Galv |
| Diameter/Size | 7/8-9 x 3 | Bolt Mfg. Lot Number | 37238-100110141 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2023-01-19-4
DIME Test ID: 2023-01-19-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-01-27
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 01/26/2023
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 72250 | Nut Proof Load |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 1/27/2023 ✔