Summary for Test 2023-01-23-4-1
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 215443 DEA: 042J8024 EFIS: 0419000294 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-80-3.8/5.0 |
| Award Date | 04/20/2021 |
| Closeout Date | 01/03/2025 |
| Work Description | PAINT STEEL STRUCTURE. |
| Location Description | THE CITY AND COUNTY OF SAN FRANCISCO FROM 16TH STREET TO 4TH STREET. |
| QA Service Level | 1 (Verified on 02/23/2021) |
Sample Information
| Sample Taken Date | 01/23/2023 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/24/2023 |
| Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
| The quantity of what the sample constitutes | 17 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpenter |
| Title of sampler | QA | Telephone number of sampler | 4156081742 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-008-23 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 2613-01 |
|---|---|---|---|
| Heat Number(s) | 10662050, 8000014475, 32028550 | Nut Mfg. Lot Number(s) | 472199B |
| Washer Mfg. Lot Number(s) | 167117 | Bolt Specification | A325 |
| Bolt Length(s) | 4" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 7/8" X 4" | Bolt Mfg. Lot Number | L833RI |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2023-01-23-4
DIME Test ID: 2023-01-23-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2023-01-27
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 01/26/2023
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | L833R1 | 0.8750 | 69851 | 310.71 | 10.00 | A325 Wedge Tensile | spaine |
General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 1/27/2023 ✔