Summary for Test 2022-08-30-100-6

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 212737
DEA: 060S8304
EFIS: 0615000046
DIST-CO-RTE-PM06-FRE-5-44.4-45.4
Award Date05/26/2022
Closeout Date05/09/2025
Work DescriptionTUMEY GULCH ABUTMENT REHAB BR# 42-0246L/R.
Location DescriptionIN FRESNO COUNTY AT TUMEY GULCH.
QA Service Level1 (Verified on 09/25/2018)

Sample Information

Sample Taken Date08/30/2022 Sample Unique Key100
Date that the sample was received by the laboratory/organization performing the testing08/31/2022 Sample typeQuality Control
A brief description of the sample4 x 8 concrete cylinders The quantity of what the sample constitutesGirder
From where was the sample collectedManufacturer First name of sampler or witnessed byRoberto
Last name of sampler or witnessed byReyes Title of samplerQC Technician
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCon-Fab California, LLC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameTumey Gulch Bridge
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSCCS98OF
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected2702
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of the truck Chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-08-30-100
DIME Test ID: 2022-08-30-100-6
Testing Lab: Con-Fab California Corporation - Shafter
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-01-26

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Roberto Reyes Perez
Date of test: 08/06/2022
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 9.2 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 98575 lb
Maximum load on cylinder 2: 95630 lb
Maximum load on cylinder 3: 101890 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 7860 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/26/2023 ✔