Summary for Test 2022-12-08-49-1

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 993318
DEA: 11423704
EFIS: 1116000059
DIST-CO-RTE-PM11-SD-8-R31.8/R41.7
Award Date04/01/2022
Closeout Date04/08/2025
Work DescriptionPLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM.
Location DescriptionSAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE
QA Service Level1 (Verified on 10/27/2021)

Sample Information

Sample Taken Date12/08/2022 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/09/2022
Sample typeQuality Control A brief description of the samplestructural concrete
The quantity of what the sample constitutes5 cy From where was the sample collectedJob Site
First name of sampler or witnessed byJustin Last name of sampler or witnessed byMcCabe
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWemco Batch Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3-22-STRC-294
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedHorses thieve bridge abutment pour Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-12-08-49
DIME Test ID: 2022-12-08-49-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-01-23

Test Results


Number of specimens: 2
Input Type: Calculated
Tester's full name: Larry Fukushima
Date of test: 01/05/2023
Correction factor: 1
Cylinder Age: 28 days
Break Description of Cylinder 1 (if not 'cone'): no data
Break Description of Cylinder 2 (if not 'cone'): no data
Average Compressive Strength (to nearest 10): 4410 lb/in^2
Compressive Strength of Cylinder 1: 4465 lb/in^2
Compressive Strength of Cylinder 2: 4346 lb/in^2
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/23/2023