Summary for Test 2022-12-22-49-1

Test performed: ASTM C78-18

Project Information

Project IdentifiersProject ID: 215348
DEA: 060U4204
EFIS: 0616000004
DIST-CO-RTE-PM06-FRE-99-R4.9/11.6
Award Date02/25/2021
Closeout DateNot set
Work DescriptionCONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location DescriptionFRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
QA Service Level1 (Verified on 12/07/2020)

Sample Information

Sample Taken Date12/22/2022 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/23/2022
Sample typeQuality Assurance A brief description of the sampleCRCP
The quantity of what the sample constitutes1000 CY From where was the sample collectedJob Site
First name of sampler or witnessed bytomas Last name of sampler or witnessed bySilva
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSecurity Paving batch plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberG3-22-PCC-291
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedUnknown
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSKIPLOADER TO WHEELBARROW Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-12-22-49
DIME Test ID: 2022-12-22-49-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: ASTM C78-18: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading)
Test Release Date: 2023-01-19

Test Results


Number of specimens: 3
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Allen Oliver
Date of test: 01/19/2023
Identification number: Set #1
Width of specimen: 5.95 inch
Width of specimen 2: 6.00 inch
Width of specimen 3: 6.00 inch
Depth of specimen: 6.10 inch
Depth of specimen 2: 6.10 inch
Depth of specimen 3: 6.10 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 9000 lb
Maximum load applied 2: 9200 lb
Maximum load applied 3: 8800 lb
Curing history and apparent moisture condition of the specimen: Damp
If specimen was capped, ground or if leather shims were used: Leather Shims
Defects in specimen: None
Age of specimen: 28 days
Age of specimen in hours: no data
Modulus of rupture: 730 psi
Modulus of rupture 2: 740 psi
Modulus of rupture 3: 710 psi
Modulus of rupture average: 725 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/19/2023