Summary for Test 2023-01-13-25-2
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/13/2023 | Sample Unique Key | 25 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/13/2023 | Sample type | Aggregate Prequalification Program |
| A brief description of the sample | State Spec Concrete Sand | The quantity of what the sample constitutes | Four bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | Javier |
| Last name of sampler or witnessed by | Macias | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Construction Company Tracy | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-39-0002 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-01-13-25
DIME Test ID: 2023-01-13-25-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2023-04-19
Test Results
Number of tests: 3
Input Type: Calculated
Tester's full name: Javier Macias
Date of test: 01/13/2023
Temperature correction: 0
Temperature of solution: 75
Clay reading (test 1): 52
Sand reading (test 1): 42
Clay reading (test 2): 52
Sand reading (test 2): 41
Clay reading (test 3): 52
Sand reading (test 3): 42
Sand equivalent (test 1): 81
Sand equivalent (test 2): 79
Sand equivalent (test 3): 81
Sand equivalent before temperature correction: 81
Sand equivalent after temperature correction: 81
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/19/2023 ✔