Summary for Test 2023-01-05-1-2
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 212085 DEA: 07296604 EFIS: 0713000057 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10-14.0/19.0 |
| Award Date | 06/04/2018 |
| Closeout Date | 05/04/2023 |
| Work Description | PAINT AND REHABILITATE BRIDGE - (STRAIN (PAINT AND INSTALL CATWALK) |
| Location Description | IN THE CITY OF LOS ANGELES, AT SANTA MONICA VIADUCT (BR. NO. 53-1301). PAINT AND REHABILITATE BRIDGE |
| QA Service Level | 1 (Verified on 07/25/2018) |
Sample Information
| Sample Taken Date | 01/05/2023 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/12/2023 |
| Sample type | Quality Assurance | A brief description of the sample | ASTM A325 TC Bolt Assembly |
| The quantity of what the sample constitutes | 760 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | H. James | Last name of sampler or witnessed by | Joo |
| Title of sampler | QA Inspector | Telephone number of sampler | 562-447-5379 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Page Industrial | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L163-001-23 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 36501-1000216027 |
|---|---|---|---|
| Heat Number(s) | 1000216027 | Nut Mfg. Lot Number(s) | 36256-223185 |
| Washer Mfg. Lot Number(s) | 1221-163 | Bolt Specification | ASTM A3125-F1852 |
| Bolt Length(s) | 2" | Nut Specification | A563 DH |
| Washer Specification | F436 | Finish | Mechanical Galv. |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 36501-1000216027 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2023-01-05-1
DIME Test ID: 2023-01-05-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-01-20
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 01/13/2023
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1B | 53090 | Nut Proof Load |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 1/20/2023 ✔