Summary for Test 2023-01-05-5-2
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/05/2023 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/10/2023 |
| Sample type | Quality Assurance | A brief description of the sample | ASTM 5/8 X 1 3/4 A325 BOLT |
| The quantity of what the sample constitutes | 200 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Timber | Last name of sampler or witnessed by | Loveland |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 435538344 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | UIS Lindon UT | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L170-013-23 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0160768 |
|---|---|---|---|
| Heat Number(s) | 20794700-201810-B57380 | Nut Mfg. Lot Number(s) | 33908-201810 |
| Washer Mfg. Lot Number(s) | E0076 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 1.75" | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | ASTM B695 |
| Diameter/Size | 5/8" | Bolt Mfg. Lot Number | M5482 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2023-01-05-5
DIME Test ID: 2023-01-05-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-01-20
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 01/13/2023
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1B | 36217 | Nut Proof Load |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 1/20/2023 ✔