Summary for Test 2022-12-20-37-3

Test performed: ASTM D624-00r20

Project Information

Project IdentifiersProject ID: 209698
DEA: 072332E4
EFIS: 0700000391
COOP: 0705187
DIST-CO-RTE-PM07-LA-I-5-45.4/54
Award Date07/01/2021
Closeout DateNot set
Work DescriptionAddition of 14 miles of HOV lanes in both directions would extend existing carpool lanes on the I- 5 in San Fernando Valley to Santa Clarita Valley
Location DescriptionThe I-5 North Capacity Enhancements Project focuses on improvements to the I-5 freeway from cities of Santa Clarita and Castaic, beginning at the SR-14 interchange to Parker Rd.
QA Service Level2 (Verified on 02/03/2021)

Sample Information

Sample Taken Date12/20/2022 Sample Unique Key37
Date that the sample was received by the laboratory/organization performing the testing12/27/2022 Sample typeQuality Assurance
A brief description of the sampleBearing Pad The quantity of what the sample constitutes5
From where was the sample collectedFabricator First name of sampler or witnessed byBrad
Last name of sampler or witnessed byStreeter Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameScougal Rubber
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)22178-1
Material/Compound/Elastomer IDNA Samples Representing243
Description (size)2x10x14 Comments
Description (Number of Shims)4 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)Scougal Rubber
Batch NumberNA

Test Details

DIME Sample ID: 2022-12-20-37
DIME Test ID: 2022-12-20-37-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2023-01-12

Test Results


Number of specimens tested: 3
Input Type: Measured
Tester's full name: r.macias
Date of test: 01/06/2023
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.075
Sample 1 Tear Strength: 210.9
Sample 2 Median Thickness: 0.063
Sample 2 Tear Strength: 194.3
Sample 3 Median Thickness: 0.065
Sample 3 Tear Strength: 193.4
UTM: 2kip
Median of the Tear Strength Values: 194.3 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Sample 2

Source: Bluehill Data Point File
Test graph for Sample 1

Source: Bluehill Data Point File
Test graph for Sample 3

Test was verified on 1/12/2023