Summary for Test 2022-11-10-52-3
Test performed: CTM 523-May 2020Project Information
| Project Identifiers | Project ID: 214524 DEA: 07304504 EFIS: 0714000067 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-57-R0.0/R4.5 |
| Award Date | 06/11/2020 |
| Closeout Date | 04/03/2025 |
| Work Description | CONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK. |
| Location Description | LOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION |
| QA Service Level | 1 (Verified on 08/12/2020) |
Sample Information
| Sample Taken Date | 11/10/2022 | Sample Unique Key | 52 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/11/2022 |
| Sample type | Quality Assurance | A brief description of the sample | CRCP Beams |
| The quantity of what the sample constitutes | 10 Cubic Yards | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Edmond | Last name of sampler or witnessed by | Jabbour |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 22-3024 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vanguard Batch Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 57030SL |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 13430 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Wheelbarrow | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-11-10-52
DIME Test ID: 2022-11-10-52-3
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2023-01-05
Test Results
Number of specimens: 2
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: Yes
Input Type: Measured
Tester's full name: Julian Calderon
Date of test: 12/08/2022
Identification number: 22-3024
Width of specimen: 6.0 inch
Width of specimen 2: 6.0 inch
Depth of specimen: 6.0 inch
Depth of specimen 2: 6.1 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Maximum load applied: 8520 lb
Maximum load applied 2: 8558 lb
Correction Factor: 1
Correction Factor 2: 0.97
Curing history and apparent moisture condition of the specimen: ok
If specimen was capped, ground or if leather shims were used: 0
Defects in specimen: 0
Age of specimen: 28 days
Age of specimen in hours: no data
Modulus of rupture: 710 psi
Modulus of rupture 2: 670 psi
Modulus of rupture average: 690 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/5/2023 ✔