Summary for Test 2016-11-04-3-2
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 7285 DEA: 040120T4 EFIS: 0400000027 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-12.6/13.9 |
Award Date | 11/27/2012 |
Closeout Date | Not set |
Work Description | CONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES |
Location Description | THE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL |
QA Service Level | 1 (Verified on 10/29/2012) |
Sample Information
Sample Taken Date | 11/04/2016 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/09/2016 |
Sample type | Quality Assurance | A brief description of the sample | End Anchors |
The quantity of what the sample constitutes | 12 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | HRC CMC Rebar | Transportation Laboratory (TL) Number | C939668 C939669 C939670 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L0810616 L0810716 L0810816 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 4060422, 4060047, 4060282 | Head Manufacturer Lot Number(s) | 1 4, 1 3, 1 4 |
Rebar Size | #9, 10, 11 | Headed Bar Model Name | HRC 220 150 |
Size of Head | Reduced Size - 4x | Head Connection Type | Friction Weld |
Head Shape | Circular | Rebar Manufacturer | CMC Rebar |
Head Manufacturer | HRC | Head Fabricator | CMC Rebar |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2016-11-04-3
DIME Test ID: 2016-11-04-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2016-11-10
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 11/10/2016
UTM: 400KIP
Temperature: 72 F
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 1 | 96430 | 96430 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 11/10/2016 ✔