Summary for Test 2022-11-15-59-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 214336 DEA: 07302404 EFIS: 0713000488 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-101-37/40 |
| Award Date | 11/17/2020 |
| Closeout Date | 09/24/2024 |
| Work Description | PADRE JUAN REHAB |
| Location Description | VEN 101 |
| QA Service Level | 1 (Verified on 02/26/2021) |
Sample Information
| Sample Taken Date | 11/15/2022 | Sample Unique Key | 59 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/16/2022 | Sample type | Quality Assurance |
| A brief description of the sample | Concrete Cylinders JPCP | The quantity of what the sample constitutes | 10 Cubic Yards |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Harrison |
| Last name of sampler or witnessed by | Kain | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 22-3040 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | n/a | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | G3-21-PCC-249R |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 10027 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Wheelbarrow | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-11-15-59
DIME Test ID: 2022-11-15-59-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-12-29
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Nathan Ogbasellasie
Date of test: 12/27/2022
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 5.95 in
Average diameter of cylinder 2: 5.96 in
Average diameter of cylinder 3: 5.95 in
Maximum load on cylinder 1: 181490 lb
Maximum load on cylinder 2: 173624 lb
Maximum load on cylinder 3: 174152 lb
Type of fracture pattern of cylinder 1: 6
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 42 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 27.81 in^2
Cross sectional area of cylinder 2: 27.9 in^2
Cross sectional area of cylinder 3: 27.81 in^2
Compressive strength (to nearest 10 psi): 6340 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/29/2022 ✔