Summary for Test 2016-11-01-6-1

Test performed: ASTM A615-15

Project Information

Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Award Date11/05/2015
Closeout Date01/18/2022
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
QA Service Level1 (Verified on 10/15/2015)

Sample Information

Sample Taken Date11/01/2016 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing11/07/2016 Sample typeQuality Assurance
A brief description of the sampleWilliams Thread Bars The quantity of what the sample constitutes2
From where was the sample collectedManufacturer First name of sampler or witnessed byGreg
Last name of sampler or witnessed byJohnston Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameWilliams Form
Transportation Laboratory (TL) NumberC731319 Inspector Lot Number from the Transportation Laboratory (TL) FormL5303716
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar SizeUnknown
Nut Specification for Threaded BarNA System ManufacturerWilliams Form
Epoxy Coating ColorPurple Threaded Bar ApplicationSoil Nail
Coating StandardsASTM A934 epoxy Bar Heat Number(s)NF16203245
Nut Heat Number(s)Unknown Bar Lot Number
Nut Lot Number Coupler Heat Number(s)
Coupler Grade

Test Details

DIME Sample ID: 2016-11-01-6
DIME Test ID: 2016-11-01-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2016-11-08

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 11/08/2016
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
11#9 Bar Heat #NF16203245L6715116L53037161124486937948.3A165 BarFred

General comments (publicly viewable) (Max 1000 characters): A165 Bar
Test Graph
Source: Partner Data Point File