Summary for Test 2022-11-22-45-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 55555 DEA: AMRL EFIS: AMRL |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for AASHTO Materials Reference Laboratory (AMRL). |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/22/2022 | Sample Unique Key | 45 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/22/2022 | Sample type | Proficiency |
| A brief description of the sample | SAMPLE 45 (A) 1/2 HMA Type A | The quantity of what the sample constitutes | 1 box 4 small bags in side |
| From where was the sample collected | Source | First name of sampler or witnessed by | Glenn |
| Last name of sampler or witnessed by | Glenn | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 022-098 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AASHTO resource | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2022-11-22-45
DIME Test ID: 2022-11-22-45-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-12-20
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Glenn Bradley
Date of test: 12/20/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.06 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 4.90 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/20/2022 ✔