Summary for Test 2022-11-22-46-2
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 55555 DEA: AMRL EFIS: AMRL |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for AASHTO Materials Reference Laboratory (AMRL). |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/22/2022 | Sample Unique Key | 46 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/22/2022 |
| Sample type | Proficiency | A brief description of the sample | SAMPLE 46 (B) 1/2 HMA Type A |
| The quantity of what the sample constitutes | 1 box 4 small bags in side | From where was the sample collected | Source |
| First name of sampler or witnessed by | Glenn | Last name of sampler or witnessed by | Bradley |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 022-098 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | AASHTO resource | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2022-11-22-46
DIME Test ID: 2022-11-22-46-2
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2022-12-20
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Glenn Bradley
Date of test: 12/20/2022
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 1525.1 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 131.4 grams | 91.4 % | |||||
| 263.2 grams | 82.7 % | |||||
| 682.8 grams | 55.2 % | |||||
| 993.2 grams | 34.9 % | |||||
| 1077.3 grams | 29.4 % | |||||
| 1121.8 grams | 26.4 % | |||||
| 1195.5 grams | 21.6 % | |||||
| 1372.9 grams | 10 % | |||||
| 1469.3 grams | 3.7 % | |||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/20/2022 ✔