Summary for Test 2016-10-07-1-1
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 209141 DEA: 07215954 EFIS: 0700001835 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-0.0/7.6 |
Award Date | 04/24/2014 |
Closeout Date | 07/14/2022 |
Work Description | WIDENING FREEWAY AND RECONSTRUCT OVERHEAD AND OVERCROSSING STRUCTURES |
Location Description | LOS ANGELES COUNTY IN LA MIRADA, SANTA FE SPRINGS, NORWALK AND DOWNEY FROM ORANGE COUNTY/LOS ANGELES COUNTY LIMIT LINES TO 0.7 MILE NORTH OF ROUTE 605 |
QA Service Level | 1 (Verified on 06/02/2014) |
Sample Information
Sample Taken Date | 10/07/2016 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/08/2016 |
Sample type | Quality Assurance | A brief description of the sample | RW 314 footing |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Armando Hernandez | Last name of sampler or witnessed by | Hernandez |
Title of sampler | ASR | Telephone number of sampler | 949-279-8453 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | SPC | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | 53E0213 |
Structure name | RW 314 |
Material Information
Material Type | Concrete | The concrete mix design number | G3-15-3600-590 |
---|---|---|---|
The truck number from where the sample was collected | load 18 | The batch plant ticket number from where the sample was collected | 37129 |
Concrete batch plant | SPC onsite batch plant | The fabricator/manufacturer designation for the sample | on site batch plant |
A detailed description of where the material sample was collected | CHUTE FROM TRUCK | Where the material sample would have been placed if not sampled | RW Footing |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-10-07-1
DIME Test ID: 2016-10-07-1-1
Testing Lab: CT D07 - Santa Fe Springs Field Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2016-11-06
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tuan Nguyen
Date of test: 11/03/2016
Average diameter of cylinder 1: 6 in
Average diameter of cylinder 2: 6 in
Maximum load on cylinder 1: 112649 lb
Maximum load on cylinder 2: 126468 lb
Type of fracture pattern of cylinder 1: 6
Type of fracture pattern of cylinder 2: 6
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 27 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 3984.8 psi
Compressive strength of cylinder 2: 4473.6 psi
Compressive strength (to nearest 10 psi): 4230 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/6/2016 ✔