Summary for Test 2016-10-07-1-1

Test performed: CTM 521-November 2014

Project Information

Project IdentifiersProject ID: 209141
DEA: 07215954
EFIS: 0700001835
DIST-CO-RTE-PM07-LA-5-0.0/7.6
Award Date04/24/2014
Closeout Date07/14/2022
Work DescriptionWIDENING FREEWAY AND RECONSTRUCT OVERHEAD AND OVERCROSSING STRUCTURES
Location DescriptionLOS ANGELES COUNTY IN LA MIRADA, SANTA FE SPRINGS, NORWALK AND DOWNEY FROM ORANGE COUNTY/LOS ANGELES COUNTY LIMIT LINES TO 0.7 MILE NORTH OF ROUTE 605
QA Service Level1 (Verified on 06/02/2014)

Sample Information

Sample Taken Date10/07/2016 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing10/08/2016 Sample typeQuality Assurance
A brief description of the sampleRW 314 footing The quantity of what the sample constitutes1
From where was the sample collectedJob Site First name of sampler or witnessed byArmando Hernandez
Last name of sampler or witnessed byHernandez Title of samplerASR
Telephone number of sampler949-279-8453 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameSPC
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier53E0213 Structure nameRW 314
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3-15-3600-590
The truck number from where the sample was collectedload 18 The batch plant ticket number from where the sample was collected37129
Concrete batch plantSPC onsite batch plant The fabricator/manufacturer designation for the sampleon site batch plant
A detailed description of where the material sample was collectedCHUTE FROM TRUCK Where the material sample would have been placed if not sampledRW Footing
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-10-07-1
DIME Test ID: 2016-10-07-1-1
Testing Lab: CT D07 - Santa Fe Springs Field Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2016-11-06

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tuan Nguyen
Date of test: 11/03/2016
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 112649 lb
Maximum load on cylinder 2: 126468 lb
Type of fracture pattern of cylinder 1: 6
Type of fracture pattern of cylinder 2: 6
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 27 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 3984.8 psi
Compressive strength of cylinder 2: 4473.6 psi
Compressive strength (to nearest 10 psi): 4230 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/6/2016 ✔