Summary for Test 2022-10-14-65-1
Test performed: CTM 521-June 2012Project Information
| Project Identifiers | Project ID: 993287 DEA: 112T35U4 EFIS: 1121000195 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-R37.4/R52.6 |
| Award Date | 09/07/2021 |
| Closeout Date | Not set |
| Work Description | CMSTPL-6211(148) I-5 N Coast Corridor HOV Extension Carlsbad |
| Location Description | IN SAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM LOMAS SANTA FE DRIVE UNDERCROSSING TO 0.2 MILES NORTH OF OCEANSIDE BOULEVARD UNDERCROSSING |
| QA Service Level | 1 (Verified on 09/23/2021) |
Sample Information
| Sample Taken Date | 10/14/2022 | Sample Unique Key | 65 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/15/2022 |
| Sample type | Quality Control | A brief description of the sample | Structural Concrete |
| The quantity of what the sample constitutes | 2 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Justin | Last name of sampler or witnessed by | McCabe |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cal portland | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 0038621 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 103182 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | paving nothces SB x10 | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-10-14-65
DIME Test ID: 2022-10-14-65-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-12-16
Test Results
Number of specimens: 2
Input Type: Calculated
Tester's full name: Larry Fukushima
Date of test: 11/11/2022
Correction factor: 1
Cylinder Age: 28 days
Break Description of Cylinder 1 (if not 'cone'): side
Break Description of Cylinder 2 (if not 'cone'): shear
Average Compressive Strength (to nearest 10): 4510 lb/in^2
Compressive Strength of Cylinder 1: 124620 lb/in^2
Compressive Strength of Cylinder 2: 130180 lb/in^2
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/16/2022 ✔