Summary for Test 2016-10-26-5-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 210696 DEA: 080M2804 EFIS: 0800000472 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-171.8/173.8 |
Award Date | 11/04/2015 |
Closeout Date | 08/21/2018 |
Work Description | BRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT. |
Location Description | In SBD County |
QA Service Level | 1 (Verified on 10/19/2015) |
Sample Information
Sample Taken Date | 10/26/2016 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/31/2016 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jose | Last name of sampler or witnessed by | del Rio |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 942-08 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | On site | Transportation Laboratory (TL) Number | 942-08 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | P40AF023SP |
---|---|---|---|
The truck number from where the sample was collected | 8049 | The batch plant ticket number from where the sample was collected | AtJobsite |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | Concrete from wheelbarrow | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-10-26-5
DIME Test ID: 2016-10-26-5-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-11-03
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 11/02/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.97 in
Maximum load on cylinder 1: 122160 lb
Maximum load on cylinder 2: 124130 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 27.99 in^2
Compressive strength of cylinder 1: 4364.4 psi
Compressive strength of cylinder 2: 4434.8 psi
Compressive strength (to nearest 10 psi): 4400 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/3/2016 ✔