Summary for Test 2022-12-08-15-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 214670
DEA: 07331004
EFIS: 0716000220
DIST-CO-RTE-PM07-VEN-101-9.0/9.2
Award Date04/13/2022
Closeout Date11/06/2024
Work DescriptionCONCRETE SLAB REPLACEMENT & GRIND, PAVEMENT & RESURFACE ACE
Location DescriptionVENTURA COUNTY IN THOUSAND OAKS FROM NORTHBOUND OFF-RAMP TO SOUTHBOUND OFF-RAMP AT CONEJO COMMERCIAL VEHICLE ENFORCEMENT FACILITIES
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date12/08/2022 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/08/2022
Sample typeDepartment Acceptance A brief description of the sampleISR-RSC
The quantity of what the sample constitutes200 CY plus From where was the sample collectedJob Site
First name of sampler or witnessed byPHILIP Last name of sampler or witnessed byMAQUIRAN
Title of samplerMREA Telephone number of sampler12133581518
Laboratory sample identification22-3165 Linked DIME Sample ID
The fabricator/manufacturer/facility namePowell Construction Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedWheelbarrow from Chute volumetric truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-12-08-15
DIME Test ID: 2022-12-08-15-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2022-12-11

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 12/11/2022
Identification number: 22-3165
Width of specimen: 6.0625 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6.0625 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.0625 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 9190 lb
Maximum load applied 2: 8442 lb
Maximum load applied 3: 8652 lb
Curing history and apparent moisture condition of the specimen: Ok
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 780 psi
Modulus of rupture 2: 720 psi
Modulus of rupture 3: 750 psi
Modulus of rupture average: 750 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/11/2022