Summary for Test 2022-11-09-24-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date11/09/2022 Sample Unique Key24
Date that the sample was received by the laboratory/organization performing the testing11/10/2022 Sample typeQuality Control
A brief description of the sample4 x 8 concrete cylinders The quantity of what the sample constitutes90 Cy
From where was the sample collectedJob Site First name of sampler or witnessed bydaniel
Last name of sampler or witnessed byjones Title of samplerTET
Telephone number of sampler Laboratory sample identificationC10256
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCT675F25
The truck number from where the sample was collected8 The batch plant ticket number from where the sample was collected6947
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-11-09-24
DIME Test ID: 2022-11-09-24-1
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2022-12-09

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Leif Ayres
Date of test: 12/06/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 162500 lb
Type of fracture pattern of cylinder 1: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 26 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 12930 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/9/2022