Summary for Test 2022-11-17-31-6

Test performed: AASHTO T96-02r10

Project Information

Project IdentifiersProject ID: 993844
DEA: 070W1004
EFIS: 0721000043
DIST-CO-RTE-PM07-LA-5-31.8/42.6
Award Date06/28/2022
Closeout DateNot set
Work DescriptionPLACE RUBBERIZED HMA (GAP GRADED)
Location DescriptionLOS ANGELES COUNTY IN BURBANK AND LOS ANGELES FROM COHASSET STREET UNDERCROSSING TO ROXFORD STREET UNDERCROSSING
QA Service Level1 (Verified on 09/20/2022)

Sample Information

Sample Taken Date11/17/2022 Sample Unique Key31
Date that the sample was received by the laboratory/organization performing the testing11/22/2022 Sample typeVerification
A brief description of the sampleJMF 3/4" RHMA-G-SP 0.50% LAS The quantity of what the sample constitutes8 Bags of Aggregate
From where was the sample collectedManufacturer First name of sampler or witnessed byVulcan
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification0749G-22
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Materials-Irwindale
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number226108 SVA3 VLO A detailed description of where the material sample was collectedVulcan Materials Irwindale
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2022-11-17-31
DIME Test ID: 2022-11-17-31-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2022-12-07

Test Results


Input Type: Calculated
Tester's full name: Robert Jarquin
Date of test: 11/29/2022
Grading designation: C
Percent loss after 100 revolutions: 6 %
Percent loss after 500 revolutions: 26 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/7/2022 ✔