Summary for Test 2022-11-28-19-3

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date11/28/2022 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing11/30/2022 Sample typePer Request
A brief description of the samplePG Asphalt Binder The quantity of what the sample constitutes1 Quart Can
From where was the sample collectedSupplier First name of sampler or witnessed byVICTOR
Last name of sampler or witnessed byPham Title of sampler
Telephone number of sampler Laboratory sample identification0761-22
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Irwindale
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2022-11-28-19
DIME Test ID: 2022-11-28-19-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-12-09

Test Results


Phase: RTFO residue
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 12/01/2022
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 88.3 degree
Dynamic Shear, G*/sin(δ): 2.40 kPa
General comments (publicly viewable) (Max 1000 characters): RTFO

Test was verified on 12/9/2022