Summary for Test 2016-10-14-6-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 211831 DEA: 11392604 EFIS: 1114000081 MINOR: 11A2458 |
|---|---|
| DIST-CO-RTE-PM | 11--8-9.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 10/12/2016) |
Sample Information
| Sample Taken Date | 10/14/2016 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/18/2016 | Sample type | Quality Assurance |
| A brief description of the sample | Flash Welded Rebar Hoops | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Tory |
| Last name of sampler or witnessed by | Mclaurin | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | TNT Rebar Nucor |
| Transportation Laboratory (TL) Number | C730521 | Inspector Lot Number from the Transportation Laboratory (TL) Form | L6728916 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | PL16101720 |
| Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 5 |
| Diameter of Hoop | 2'-8" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-10-14-6
DIME Test ID: 2016-10-14-6-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-10-20
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/19/2016
UTM: 75KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 1 | #5/16mm | 0.31 | 30944 | 99820 | necking okay | Fred |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.
Test was verified on 10/20/2016 ✔