Summary for Test 2016-10-13-5-8
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 211068 DEA: 080N5504 EFIS: 0800020102 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-40-R105.2/R106.5 |
| Award Date | 04/21/2016 |
| Closeout Date | 08/09/2018 |
| Work Description | REPLACE THE LEFT WATSON WASH BRIDGE N0. 0805L |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 05/10/2016) |
Sample Information
| Sample Taken Date | 10/13/2016 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/18/2016 | Sample type | Quality Assurance |
| A brief description of the sample | Flash Welded Rebar Hoops | The quantity of what the sample constitutes | 12 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | RM |
| Last name of sampler or witnessed by | Granados | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | TNT Rebar Cascade |
| Transportation Laboratory (TL) Number | C970357 | Inspector Lot Number from the Transportation Laboratory (TL) Form | L1022316 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 247516 |
| Hoop Manufacturer Lot Number(s) | 18, 25, 27 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 5 |
| Diameter of Hoop | 1'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-10-13-5
DIME Test ID: 2016-10-13-5-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-10-20
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/19/2016
UTM: 75KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 27 | #5/16mm | 0.31 | 30309 | 97770 | necking okay | Fred |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.
Test was verified on 10/20/2016 ✔